Notice: Trying to access array offset on value of type bool in /var/www/vhosts/ric-co.ir/httpdocs/includes/TempFns.inc.php on line 321

Warning: include(/var/www/vhosts/ric-co.ir/httpdocs/includes/tpls/rahbord/includes/FA.inc.php): failed to open stream: No such file or directory in /var/www/vhosts/ric-co.ir/httpdocs/includes/tpls/rahbord/SC.php on line 8

Warning: include(): Failed opening '/var/www/vhosts/ric-co.ir/httpdocs/includes/tpls/rahbord/includes/FA.inc.php' for inclusion (include_path='.:/opt/plesk/php/5.6/share/pear') in /var/www/vhosts/ric-co.ir/httpdocs/includes/tpls/rahbord/SC.php on line 8
0913-612-4112
  • (0 )
  • ورود / عضویت
سبد خرید شما خالی است.
جستجو کنید...

Notice: Undefined index: pro_perm in /var/www/vhosts/ric-co.ir/httpdocs/components/DCMS/Shop/GLBFns.inc.php on line 1098

Notice: Undefined index: pro_perm in /var/www/vhosts/ric-co.ir/httpdocs/components/DCMS/Shop/GLBFns.inc.php on line 1098

Notice: Undefined index: pro_perm in /var/www/vhosts/ric-co.ir/httpdocs/components/DCMS/Shop/GLBFns.inc.php on line 1098
 
 

کابل شبکه Cat6 UTP CCA

کاربرد

 قابل استفاده در محیط داخل ساختمان

استفاده در شبکه های کامپیوتری 

قابل کاربرد در سیستمهای متحرک

استفاده در شبکه های صنعتی

نصب با فشار هوا 

نصب مستقیم کانکتور

نصب و استفاده اسان و راحت



5,300,000 ریال
  • خصوصیات ویژه محصول
  • تغییرات ممکن
  • مشخصات فنی
  • کلمات کلیدی
  • نظرات کاربران

 مواد اولیه با کیفیت

سیم آلومینیوم با روکش مس

فرکانس بالا

قبول شدن در آزمایشگاه توسط دستگاه فلوک

همراه باسیم اتصال زمین 

با روکش LSZH بدون

Specification

Recommended

Kind of Standards

ANSI/TIA-568-C.2

Construction

Conductor Material

Solid CCA

AWG

23

Insulation Material 

HDPE

Cross Filler Material 

PE

Wrapping

 

Drain Wire

NONE

Shield

None

Braid

None

Ripcord

Yes

Jacket Material 

PVC, LSZH or any

Jacket Thickness

0.56 mm

Outer Diameter

6.5 ±0.5 mm

Weight

38 g/m

Technical Performances

Test By Fluke

Pass for 70 Meter

Headroom

Min. 5 dB

Frequency

250 MHz

Min. Bending Radius

4*Dia.

Operation Temp.

-20 to +75 °C

 
  •  

 

Specification

Recommended

Kind of Standards

ANSI/TIA-568-C.2

Construction

Conductor M.

Solid CCA

AWG

23

Insulation M.

HDPE

Cross Filler M.

PE

Wrapping

 

Drain Wire

CCA

Shield

None

Braid

None

Ripcord

Yes

Jacket M.

PVC

Jacket Thickness

0.56 mm

Outer Diameter

6.5 ±0.5 mm

Weight

38 g/m

Technical Performances

Test By Fluke

Pass for 70 Meter

Headroom

Min. 5 dB

Frequency

250 MHz

Min. Bending Radius

4*Dia.

Operation Temp.

-20 to +75 °C

 
  •  